Bulletin PD-21081 08/05 MURB1020CTPbF MURB1020CT-1PBF Ultrafast Rectifier Features * * * * * Ultrafast Recovery Time Low Forward Voltage Drop Low Leakage Current 175C Operating Junction Temperature Lead-Free ("PbF" suffix) trr = 25ns IF(AV) = 10Amp VR = 200V Description/ Applications International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with optimized performance of forward voltage drop and ultra fast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as free-wheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. Absolute Maximum Ratings Parameters VRRM IF(AV) IFSM IFM TJ, TSTG Peak Repetitive Peak Reverse Voltage Average Rectified Forward Current Total Device, (Rated VR ), TC = 149C Non Repetitive Peak Surge Current Peak Repetitive Forward Current (Rated VR , Square wave, 20 KHz), TC = 149C Operating Junction and Storage Temperatures - 65 to 175 C Per Leg Total Device Per Leg Per Leg Max 200 5 10 50 10 Units V A Case Styles MURB1020CTPbF MURB1020CT-1PBF BASE COMMON CATHODE 2 BASE COMMON CATHODE 2 1 2 3 1 2 3 ANODE COMMON ANODE CATHODE 1 2 ANODE COMMON ANODE CATHODE 1 2 D2PAK www.irf.com TO-262 1 MURB1020CTPbF, MURB1020CT-1PBF Bulletin PD-21081 08/05 Electrical Characteristics @ TJ = 25C (unless otherwise specified) Parameters VBR, Vr VF Breakdown Voltage, Blocking Voltage Forward Voltage Min Typ Max Units Test Conditions 200 V V V V A A pF nH IR = 100A IF = 5A, TJ = 125C IF = 10A, TJ = 125C IF = 10A, TJ = 25C VR = V R Rated TJ = 150C, VR = V R Rated VR = 200V Measured lead to lead 5mm from package body . 0.87 0.99 1.02 1.20 1.12 1.25 8 8.0 10 250 - IR Reverse Leakage Current - CT LS Junction Capacitance Series Inductance - Dynamic Recovery Characteristics @ TJ = 25C (unless otherwise specified) Parameters trr Reverse Recovery Time Min Typ Max Units Test Conditions 24 35 35 25 ns IF = 1.0A, diF/dt = 50A/s, VR = 30V IF = 0.5A, IR = 1.0A, IREC = 0.25A TJ = 25C TJ = 125C nC A TJ = 25C TJ = 125C TJ = 25C TJ = 125C IF = 5A VR = 160V diF /dt = 200A/s IRRM Peak Recovery Current - 3.3 5.0 33 76 Qrr Reverse Recovery Charge - Thermal - Mechanical Characteristics Parameters TJ TStg RthJC RthJA RthCS Wt Max. Junction Temperature Range Max. Storage Temperature Range Thermal Resistance, Junction to Case Per Leg Min - 65 - 65 - Typ 0.5 2.0 0.07 - Max 175 175 5 50 12 10 Units C C/W Thermal Resistance, Junction to Ambient Per Leg Thermal Resistance, Case to Heatsink Weight g (oz) Kg-cm lbf.in 2 Mounting Torque 6.0 5.0 Marking Device MURB1020CT MURB1020CT-1 Case style D Pak Case style TO-262 Mounting Surface, Flat, Smooth and Greased 2 www.irf.com MURB1020CTPbF, MURB1020CT-1PBF Bulletin PD-21081 08/05 100 100 10 1 0.1 0.01 25C TJ = 175C 150C 125C 100C Instantaneous Forward Current - I F (A) 10 Reverse Current - I R (A) 0.001 0.0001 T = 175C J T = 125C J T = 25C J 0 40 80 120 160 200 Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage 100 Junction Capacitance - C T (pF) T = 25C J 1 10 0.1 0.2 1 0.4 0.6 0.8 1 1.2 1.4 1.6 1 10 100 1000 Forward Voltage Drop - VFM (V) Fig. 1 - Typical Forward Voltage Drop Characteristics Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage 10 (C/W) thJC Thermal Impedance Z 1 D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 Notes: PDM t1 t2 0.1 Single Pulse (Thermal Resistance) 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc 0.01 0.00001 0.0001 0.001 0.01 0.1 1 t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics www.irf.com 3 MURB1020CTPbF, MURB1020CT-1PBF Bulletin PD-21081 08/05 180 Allowable Case Temperature (C) Average Power Loss ( Watts ) 7 RMS Limit 6 5 4 3 2 1 0 D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 DC 170 160 150 Square wave (D = 0.50) Rated Vr applied DC 140 see note (2) 130 0 2 4 6 8 Average Forward Current - IF(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current 0 1 2 3 4 5 6 7 8 Average Forward Current - IF(AV) (A) Fig. 6 - Forward Power Loss Characteristics 50 IF = 10 A IF = 5 A 160 140 120 100 Qrr ( nC ) IF = 10 A IF = 5 A VR = 160V TJ = 125C TJ = 25C 40 trr ( ns ) 30 80 60 20 VR = 160V TJ = 125C TJ = 25C 40 20 0 100 di F /dt (A/s ) Fig. 8 - Typical Stored Charge vs. di F /dt 10 100 di F /dt (A/s ) 1000 1000 Fig. 7 - Typical Reverse Recovery vs. di F /dt (2) Formula used: TC = T J - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = V R1 x IR (1 - D); IR @ V R1 = rated VR 4 www.irf.com MURB1020CTPbF, MURB1020CT-1PBF Bulletin PD-21081 08/05 Reverse Recovery Circuit VR = 200V 0.01 L = 70H D.U.T. di F /dt dif/dt ADJUST D G IRFP250 S Fig. 9- Reverse Recovery Parameter Test Circuit 3 IF 0 t rr ta tb 4 2 Q rr I RRM 0.5 I RRM di(rec)M/dt 0.75 I RRM 5 1 /dt di fF/dt 4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 I RRM extrapolated to zero current Fig. 10 - Reverse Recovery Waveform and Definitions www.irf.com 5 MURB1020CTPbF, MURB1020CT-1PBF Bulletin PD-21081 08/05 Outlines Table BASE COMMON CATHODE 2 1 2 3 ANODE COMMON ANODE CATHODE 1 2 Conform to JEDEC outline D2Pak (SMD-220) Dimensions in millimeters and (inches) Modified JEDEC outline TO-262 Dimensions in millimeters and (inches) BASE COMMON CATHODE 2 1 2 3 ANODE COMMON ANODE CATHODE 1 2 NC 6 www.irf.com MURB1020CTPbF, MURB1020CT-1PBF Bulletin PD-21081 08/05 Part Marking Information D2PAK PART NUMBER MURB1020CT THIS IS A MURB1020CT LOT CODE 8024 ASSEMBLED ON WW 02, 2000 INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE DATE CODE YEAR 0 = 2000 WEEK 02 P = LEAD-FREE TO-262 THIS IS A MURB1020CT-1 LOT CODE 8024 ASSEMBLED ON WW 02, 2000 INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE PART NUMBER MURB1020CT-1 DATE CODE YEAR 0 = 2000 WEEK 02 P = LEAD-FREE www.irf.com 7 MURB1020CTPbF, MURB1020CT-1PBF Bulletin PD-21081 08/05 Tape & Reel Information TRR 1.60 (0.063) 1.50 (0.059) 4.10 (0.161) 3.90 (0.153) FEED DIRECTION 1.60 (0.063) 1.50 (0.059) DIA. 0.368 (0.0145) 0.342 (0.0135) 1.85 (0.073) 1.65 (0.065) 11.60 (0.457) 11.40 (0.449) 15.42 (0.609) 15.22 (0.601) 1.75 (0.069) 24.30 (0.957) 23.90 (0.941) TRL 10.90 (0.429) 10.70 (0.421) 1.25 (0.049) 16.10 (0.634) 15.90 (0.626) DIA. 4.72 (0.186) 4.52 (0.178) FEED DIRECTION 13.50 (0.532) 12.80 (0.504) DIA. 26.40 (1.039) 24.40 (0.961) SMD-220 Tape & Reel When ordering, indicate the part number, part orientation, and the quantity. Quantities are in multiples 60 (2.362) D IA . MIN. 360 (14.173) DIA. MAX. of 800 pieces per reel for both TRL and T RR. Dimensions in millimeters and (inches) 8 www.irf.com MURB1020CTPbF, MURB1020CT-1PBF Bulletin PD-21081 08/05 Ordering Information Table Device Code MUR 1 B 2 10 3 20 4 CT 5 -1 6 TRL PbF 7 8 1 2 3 4 5 6 7 6 8 - Ultrafast MUR Series B = D2Pak/ TO-262 Current Rating (10 = 10A) Voltage Rating (20 = 200V) CT -1 = Center Tap (Dual) TO-220 /D2PAK/ TO-262 = TO-262 none = Tube (50 pieces) TRL = Tape & Reel (Left Oriented, for D2PAk package) TRR = Tape & Reel (Right Oriented, for D 2PAk package) - none = Standard Production PbF = Lead-Free Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level and Lead-Free. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 08/05 www.irf.com 9 |
Price & Availability of MURB1020CT-1PBF |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |